Sign In | Join Free | My webtextiles.com |
|
Brand Name : HAIDA
Model Number : HD-E705
Certification : CE,ISO
Place of Origin : China
MOQ : 1 set
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 30 SET / MONTH
Delivery Time : 8 WORKING DAYS AFTER COMFIRED THE ORDER
Packaging Details : FOAM.WOOD BOX
Temperature Range : -50c To +100c
Dimension (Internal) (w x d x h) : 1500 x 1500 x 3000 Mm
Dimension (External) (w x d x h) : 2850 x 1700 x 3200 Mm
Accuracy : Temp. ±1c, Humidity ±2.5%Rh
Product Name : Walk in chamber
Temperature And Humidity Test Chamber/Walk In Chamber With Environmental
Walk In Chamber Ovreview:
walk in chamber is a environment test chamber with temperature and humidity testing.walk in chamber can accurately simulate low-temperature, high temperature, high temperature and humidity, low temperature and humidity and other complex natural environment, applicable to plastics, electronics, food, clothing, vehicles, metals, chemicals, building materials and other industries in the reliability of product testing.
This walk in chamber have a large chamber size (2850 x 1700 x 3200 Mm) for diffirence products to make a test.and it is easy to operate with touch screen system.and you will observe the sample testing by viewing windows.
Walk In Chamber Application Test Items:
Walk In Chamber Application Metarial or Industry:
Test Standard(including but not limited to... ):
Compliance with ASTM G53-77 specifications GB, GJB, MIL, ASTM, CNS, IEC, JIS, AATCC, DIN, Fed Test, BS and SAE.
Specifications:
Sr No | Specification | Hd-E705-7-1 |
1 | Temperature Range | -50c To +100c |
2 | Humidity Range | 40% To 98% Rh |
3 | Dimension (Internal) (w x d x h) | 1500 x 1500 x 3000 Mm |
4 | Dimension (External) (w x d x h) | 2850 x 1700 x 3200 Mm |
5 | Ramp | Variable, Temp. 0~5c / Min & Humidity 0~5%/Min |
6 | Accuracy | Temp. ±1c, Humidity ±2.5%Rh |
7 | Interior Walls | Stainless Steel 304 |
8 | Exterior Walls | Cold Rolled Stell Plate With Baking Finish |
9 | Temperature & Humidity Measurement And Controller | 32 Bit Control And Monitoring System. |
10 | Viewing Window | Multi Pane Glass Window Size |
11 | Port Holes | 50 Mm Diameter For Wire Routing |
12 | Power Supply Requirement | Three Phase, Ac380 v ± 10 %, 50 Hz |
13 | Sound Pressure Level | <72db (a) |
14 | Condenser Cooling | Water Cooled |
(The above parameters are machine standard parameters and can be customized according to your requirements)
Chamber Pictures:
![]() |
Temperature And Humidity Test Chamber/Walk In Chamber With Environmental Images |